Dry Type
Reactor |
|
| ¡¡ |
|
¡¡ |
In 1991, SUNTEN was designated to develop cast resin
insulated dry type reactor by Mechanical Industry Department
and Electronic Department. Up to now, Sunten has owned over ten patents
for the two types of reactor ( steel core and
air core) including shunt reactor, series
reactor, arc-supression coil assembly, earthing
transformers, initiating transformers, current limiting
transformers, TCR shunt reactor, filtering reactor. The
voltage class is up to 35kV, the capacity is up to 30000
kvar for steel-core reactor; for air-core reactor, the
voltage class is up to 66kV, the capacity is up to 32800kvar
per single phase. |
|
|
|
---Series
Products--- |
|
►
TCR Shunt Reactor for SVC |
►
Shunt Reactor |
|
No Photo |
 |
| Type:
BKDCKL-2x20000/33 |
Type:
BKSC-16000/35 |
| Main Technical Parameters:
Rated
power:2x2500~2x20000kvar,
Rated voltage: up to 63kV
Sound level: below 63dB
Heat Resist class: F
Insulation class:
10kV LI 75 AC 45, 35kV LI 200 AC 85,
63kV LI 325
AC 125,
Working condition: outdoor.
|
Main Technical Parameters:
Rated power:1500~16000kvar,
Rated voltage: up to 35kV
Sound level: below 57dB
Heat Resist class: F
Insulation class: 10kV LI 75 AC 35, 35kV LI 200
AC 85,
Reactance deviation: 3%,
Working condition: outdoor or indoor.
|
|
Main Service Range:
SVC system of iron
and steel, petro-chemical industries
|
Main Service Range:
up to 35kV
power system of power plant,
industrial and mining enterprises, user
distribution substation.
|
|
|
|
|
|
►
Series Reactor |
►
Series Reactor |
 |
 |
|
Product Type:
CKSC-1200/35-12 |
Product Type:
CKSCKL-7200/35-12 |
| Main
Technical Parameters:
Rated
power:6~1200kvar,
Rated voltage: up to 35kV
Sound level: below 60dB
Heat Resist Class: F,
Insulation: 10kV LI 75 AC 35, 35kV LI 200 AC 85,
Reactance deviation: 5%,
Working condition: outdoor or indoor.
|
Main Technical
Parameters:
Rated power 6~7200kvar,
Rated voltage: 63kVand below
Sound level: below 60dB
Heat Resist class: F
Insulation class: 10kV LI 75 AC 35,
35kV LI 200
AC 85, 63kV LI 325 AC 125,
Working condition: outdoor or indoor.
|
|
Main Service Range:
up to 35kV power
system of power plant, industrial and mining
enterprises, user distribution substation.
|
Main Service Range:
up to 63kVpower system of power plant,
industrial and mining enterprises, distribution substation.
|
|
|
|
|
|
►
Single-phase Shunt Reactor |
►
Resistance Earthing System |
 |
No Photo |
| Product
Type: BKDCKL-20000/35 |
Product
Type: DZSC-10-400 |
|
Main Technical Parameters:
Rated power:
3333~30000kvar,
Rated voltage:up to 63kV
Sound level: below 56dB,
Heat Resistant class: F
Insulation class: 10kV LI 75 AC 45, 35kV LI 200
AC 85, 63kV LI 325 AC 125,
Working condition: outdoor
|
Main
Technical Parameters:
Rated
power:6~7200kvar,
Rated voltage:up to 35kV
Sound level: below 56dB
Heat resist class of earthing system: F
Insulation class: 10kV LI 75 AC 35, 35kV LI 1700
AC 85,
Working condition: outdoor or indoor
Temperature rise (10s, rated current): 760K,
Reactance deviation:10%
Resistance material: imported stainless steel.
|
| Main
Service Range:
up to 35kV power system
of power plant, industrial and mining
enterprises, user distribution substation.
|
Main
Service Range:
up to 35kV power system
of power plant, industrial and mining
enterprises, user distribution substation.
|
|
|
|
|
►
Line Trap |
►
Current-limiting Reactor |
|
No Photo |
No Photo |
|
Product Type:
XZDCKL-1000-1.0/31.5 |
Product Type:
XKSCKL-10.5-4000-12 |
| Main
Technical Parameters:
Rated
current:630~3150A
Short resistant current:20~100kA
Rated voltage: up to
35kV
Heat resistant class: F
Working condition outdoor or indoor.
|
Main Technical
Parameters:
Rated current: 100~5000A,
Rated voltage: up to 63kV
Sound level: below 60dB
Heat resistant class: F
Insulation class: 10kV LI 75 AC 45
35kV LI 200AC 85,
63kV LI 325AC 125
Working condition: outdoor or indoor.
|
|
Main Service Range:
up to 35kV and below power
system of power plant, industrial and mining
enterprises, user distribution substation.
|
Main Service Range:
up to 35kV
power system of power plant,
industrial and mining enterprises, user
distribution substation.
|
|
|
|
More>> |
|
|
|
|
¡¡ |
|
|